PWP410 / PWP411 Hygienic Sanitary Pressure Level Transmitter

PWP410 and PWP411 front flush diaphragm pressure transducer have been specifically designed for the measurement of viscous, paste-like, crystallizing, or solids-containing media.
More>>
Contact Us

Product details

Datasheet download

 

Use with sanitary liquids, adhesives, greases, sealants, or frequently changing media, which could clog the pressure channel of conventional process connections. 
Thanks to the front-flush welded stainless steel membrane, it does not have dead space and is especially easy to clean. Low-maintenance and trouble-free pressure measurement is thus also guaranteed in critical applications with frequently changing media.
For high medium temperatures of up to 150℃, the pressure transmitter is also available with an integrated cooling element. High accuracy, a robust design, high quality workmanship are the key features of the model. 

 

 

Applications:

  • Food, dairy and beverage processing
  • Filling and packing machinery
  • Cleaning systems
  • Hydraulic fluids
  • Waste water treatment
  • Level measurement
  • Dosing of glues, adhesives, foams and other viscous media

 

Features:

  • Flush design prevents clogging
  • Sanitary or Clean-in Place applications
  • Expanded temperature range -40...+150℃
  • Measuring range up to 7Mpa
  • Free of dead space and easy to clean
  • Process connection in high-end stainless steel G1/2” or Tri-clamp 1-1/2”

 

Specification

Model

PWP410/PWP411

Pressure Type

Relative (gauge) /Absolute pressure/Sealed gauge pressure

Pressure Range

-0.1MPa ... 0kPa~10kPa …7MPa

Safe Overload

≤200%FS

Burst Pressure

300%FS

Electrical Connection

DIN43650 Hirschmann Connector/

M12*4pins/Directly outlet cable

Accuracy

±0.5%FS(Typical), ±0.25%FS, ±0.1%FS optional

Signal Output

4-20mA/0.5-4.5V/0-5V/0-10V/I2C/RS485

Power Supply

3.3-5VDC/4-6VDC/5-30VDC/10-30VDC

Response Time

≤3ms

Medium Compatible

Liquid compatible with ceramic and stainless steel

SUS304, SS316L material

Long-term Stability (%FS/year)

≤0.1 for 0.1%FS, ≤0.2 for 0.25%FS,  ≤0.5 for 0.5%FS

Compensation Temp.

0℃~+50℃(≤200kPa), -10℃~+60℃(>200kPa)

Working Temp.

-20℃~+85℃(Typical); -20℃~+150℃(With cooling element)

Storage Temp.

-40℃~+85℃

Service Life

>10 million load cycles (within measurement range)

Explosion Proof

Optional

IP Rating

IP65/IP67

EMC Standard

EN IEC 61326-1:2021; EN IEC 61326-2:2021

 